Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters

Database
Language
Document Type
Year range
1.
PLoS One ; 17(10): e0275482, 2022.
Article in English | MEDLINE | ID: covidwho-2065138

ABSTRACT

The persistence of high consequence public health pathogens in a wastewater treatment system can significantly impact worker safety, as well as the public and downstream water bodies, particularly if the system is forced to shut down the treatment processes. This study utilizes organism viability to compare the persistence of three pathogen surrogates in wastewater using a pilot-scale activated sludge treatment (AST) system, operated to mimic treatment processes of large-scale plants. Bacillus globigii spores, surrogate for Bacillus anthracis, persisted in the AST system for at least a 50-day observation period leading to a possible steady condition far beyond the solid retention time for sludge particles. MS2 bacteriophage, surrogate for Poliovirus and other non-enveloped enteric viruses, was observed for up to 35 days after introduction, which largely and expectedly correlated to the measured solid retention time. Phi-6 bacteriophage, a surrogate for Ebola virus and other enveloped viruses, was detected for no more than 4 days after introduction, even though the AST system was operated to provide three times slower solids removal than for the other surrogates. This suggests Phi-6 is subject to inactivation under AST conditions rather than physical removal. These results may suggest similar persistence for the surrogated pathogens, leading to appropriate consequence management actions.


Subject(s)
Sewage , Water Purification , Bacteria , Levivirus , Sewage/microbiology , Wastewater , Water , Water Purification/methods
2.
PLoS One ; 16(9): e0257434, 2021.
Article in English | MEDLINE | ID: covidwho-1443838

ABSTRACT

Although research has shown that the COVID-19 disease is most likely caused by airborne transmission of the SARS-CoV-2 virus, disinfection of potentially contaminated surfaces is also recommended to limit the spread of the disease. Use of electrostatic sprayers (ESS) and foggers to rapidly apply disinfectants over large areas or to complex surfaces has emerged with the COVID-19 pandemic. ESSs are designed to impart an electrostatic charge to the spray droplets with the goal of increasing deposition of the droplets onto surfaces, thereby promoting more efficient use of the disinfectant. The purpose of this research was to evaluate several spray parameters for different types of sprayers and foggers, as they relate to the application of disinfectants. Some of the parameters evaluated included the spray droplet size distribution, the electrostatic charge, the ability of the spray to wrap around objects, and the loss of disinfectant chemical active ingredient due to the spray process. The results show that most of the devices evaluated for droplet size distribution had an average volume median diameter ≥ 40 microns, and that four out of the six ESS tested for charge/mass produced sprays of at least 0.1 mC/kg. A minimal wrap-around effect of the spray deposition onto a cylindrical object was observed. The loss of disinfectant active ingredient to the air due to spraying was minimal for the two disinfectants tested, and concurrently, the active ingredient concentrations of the liquid disinfectants sprayed and collected 3 feet (1 meter) away from the spray nozzle do not decrease.


Subject(s)
COVID-19/prevention & control , Disinfectants/administration & dosage , Disinfection/instrumentation , Disinfectants/pharmacology , Disinfection/methods , Equipment Design , Humans , SARS-CoV-2/drug effects , Static Electricity , Surface Properties/drug effects
SELECTION OF CITATIONS
SEARCH DETAIL